High Performance
• Low Distortion Interference, Complete Input/Output Isolation
• The maximum single-phase capacity can reach 15KVA and the three-phase power supply can reach 45KVA.
• Remote voltage feedback function to ensure the consistency of test point voltage value and setting value
• Voltage and current measurements are based on high precision ADC AC sampling and digital real value calculation.
• A single chip computer (D/A circuit) is used to collect voltage and current waveform data directly. contains RS232 or RS485 interface, communicate with computer.
• Built-in soft start device can easily start motor, compressor and other high starting current load
• The central processing unit is used to control the opening and closing of logic circuits. The one-to-one driving method is beneficial to disperse heat dissipation of power components and redundant design in structure.
• Inspection of temperature and humidity in the machine, intelligent ventilation and are faction in wet weather to ensure the normal use of power supply
Humanized design
• LCD Display parameters: voltage, current, power, power factor, frequency, peak current and time
• LED Displaying voltage, current, frequency, power ( power factor)
• A group of test groups can execute 35 test points (different voltage0~300V, frequency45~500Hz, time 0.1S-999.9H settings), and can do continuous cycle (0~99999999 times) testing.
• Power supply multi-point real-time sensor monitoring, running normal code and fault code screen display, fully control the power supply status.
• The parameter calibration is accomplished by open software, and different from other power sources, the potentiometer and adjustable resistance are also adjusted in the circuit.
• Wide range of voltage and frequency regulation, digital key input, independent display of three-phase voltage and line voltage
• Digital password lock, test data security and prevent important test data from being modified by misoperation
APA1000L Single phase series
Model | 1000L | 1001L | 1002L | 1003L | 1005L | 1010L | 1015L |
---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 15KVA |
Input Power | 1Ø2W+G 110V/220V±10% 220V±10% 50/60Hz±5% | ||||||
Output Frequency | 50Hz/ 60Hz/ 45~500Hz | ||||||
Frequency stability | 0.01% | ||||||
Output Voltage | 0~150V/0~300V(AUTO) | ||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 84/42 | 126/63 |
Load Regulation | ≤0.5% | ||||||
Waveform Distortion | ≤0.3% | ||||||
Meter Display | LED/LCD Display Voltage, Current, Frequency and Power (Peak Current Time Power Factor) | ||||||
Protective Device | Overload, Overcurrent, Temperature, Short Circuit, Undervoltage Protection and Alarm | ||||||
Working condition | ambient temperature 0~40°C relative humidity10~90% |
APA1000LS Three phase series
Model | 1006LS | 1010LS | 1015LS | 1020LS | 1030LS | 1045LS |
---|---|---|---|---|---|---|
Output Capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA |
Input Power | 1Ø2W+G 220V±10% | 3Ø4W+G 220V/380V±10% 50/60Hz±5% | ||||
Output Frequency | 50Hz/ 60Hz/ 45~500Hz | |||||
Frequency stability | 0.01% | |||||
Output Voltage | 相电压 0~150V/0~300V (AUTO) | |||||
Output current | 16.8/8.4 | 27.5/13.75 | 42/21 | 55.6/27.8 | 84/42 | 126/63 |
Load Regulation | ≤0.5% | |||||
Waveform Distortion | ≤0.3% | |||||
Meter Display | LED/LCD Display Voltage, Current, Frequency and Power (Peak Current Time Power Factor) | |||||
Protective Device | Protection and alarm of short circuit, short voltage and short phase with overload, over current and over temperature | |||||
Working condition | ambient temperature 0~40°C relative humidity10~90% |