High Performance
• The maximum capacity of single-phase power supply can reach 600 KVA;three-phase power supply can reach 2000 KVA
• High crest factor 3.5:1
• Fast response, suitable for special load. Low Distortion Interference, Complete Input/Output Isolation
• Terminal voltage feedback compensation function to ensure no error in test power
• Set the starting angle of waveform (0-359 degrees)and synchronous active signal interface
• Fast operation,accurate and fast measurement of power parameters
• A single chip computer (D/A circuit) is used to collect voltage and current waveform data directly. contains RS232 or RS485 interface, communicate with computer. Five groups of test groups can be set up on a single machine. Each group can set up 35 different test points (different voltage0~300V, frequency45~500Hz, time 0.1S~999.9Hand can do (0~999999) cycle test.
• The central processing unit is used to control the opening and closing of logic circuits. The one-to-one driving method is beneficial to disperse heat dissipation of power components and redundant design in structure.
• Voltage analogue (0~5V) or current analog (4~20mA) can be used to control power output.
• Perfect Protection Function: Overload, Over current, Temperature, Short Circuit, Under voltage Protection and Alarm
• Ultra-large 7-inch touch screen displays parameters: voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle, impedance value and real-time curve of voltage and current.
APA2000 Single phase series
Model | 2000 | 2001 | 2002 | 2003 | 2005 | 2010 | 2015 | 2020 |
---|---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 15KVA | 20KVA |
Input Power | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz±5% | ||||||||
Output Frequency | 50Hz 60Hz 47~63Hz (45~500Hz match) | |||||||
Frequency stability | 0.01% | |||||||
Output Voltage | 0~150V/0~300V | |||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 84/42 | 126/63 | 168/84 |
Load Regulation | ≤1% | |||||||
Waveform Distortion | ≤1% (full load≤2%) | |||||||
Meter Display | Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current | |||||||
Protective Device | Overload, Overcurrent, Temperature, Short Circuit, Undervoltage Protection and Alarm | |||||||
Weight(kg) | 20 | 25 | 30 | 35 | 45 | 100 | 115 | 130 |
W*H*D(mm) | 425*89*480 | 430*200*500 | 430*490*700 | 430*580*700 | ||||
Working condition | ambient temperature 0~40°C relative humidity10~90% |
APA2000S Three phase series
Model | 2015S | 2020S | 2030S | 2045S | 2060S | 2075S | 2100S | 2120S |
---|---|---|---|---|---|---|---|---|
Output Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input power | 1Ø2W+G 220V±10% | 3Ø4W+G 220V/380V±10% 50/60Hz±5% | ||||||
Output Frequency | 50Hz 60Hz 47~63Hz (45~500Hz match) | |||||||
Frequency stability | 0.01% | |||||||
Output Voltage | Phase voltage 0V~150V/0~ 300V Line voltage 0V~260V/0V~520V | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Load Regulation | ≤1% | |||||||
Waveform Distortion | ≤1%(full load≤2%) | |||||||
Meter Display | Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current | |||||||
Protective Device | Protection and alarm of short circuit, short voltage and short phase with overload, over current and over temperature | |||||||
Weight(kg) | 210 | 240 | 360 | 450 | 540 | 600 | 780 | 850 |
W*H*D(mm) | 510*780*710 | 430*200*500 | 750*1500*850 | 900*1780*950 |