Product parameter 
• Input voltage range:Single phase 195~245V
Three phase 340V~420V
• Input frequency range:50/60Hz±5%
• Output voltage range:Single phase 0~300V (0~600V Match)   
Three phase 0~520V (0~1040V Match)
• Output frequency range:45~500Hz
• Waveform Distortion≤0.3%  Load Regulation≤0.5%  Frequency stability≤0.01%
• Three-phase phase angle can be adjusted (0~120 degrees),each phase in use can independently
adjust voltage and frequency, and independently display voltage and frequency linear climb and drop editing test function, can do voltage and frequency gradient and interrupt test, and has independent compensation function of impedance, can simulate various test and test power supply of power grid.

Online quote

Product details

High Performance 
• Low Distortion Interference, Complete Input/Output Isolation
• The maximum single-phase capacity can reach 15KVA and the three-phase power supply can reach 45KVA.
• Remote voltage feedback function to ensure the consistency of test point voltage value and setting value
• Voltage and current measurements are based on high precision ADC AC sampling and digital real value calculation.
• A single chip computer (D/A circuit) is used to collect voltage and current waveform data directly. 
• contains RS232 or RS485 interface, communicate with computer. Five groups of test groups can be set up on a single machine. Each group can set up 35 different test points (different voltage0~300V, frequency45~500Hz, time 0.1S~999.9H and can do (0~999999) cycle test.
• Built-in soft start device can easily start motor, compressor and other high starting current load
• The central processing unit is used to control the opening and closing of logic circuits.
• In-machine temperature and humidity detection, intelligent exhaust dehumidification, ensure the normal use of power supply

Humanized design
• Ultra-large 7-inch touch screen displays parameters: voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle, impedance value and real-time curve of voltage and current.
• Power supply multi-point real-time sensor monitoring, running normal code and fault code screen display, fully control the power supply status.
• The parameter calibration is accomplished by open software, and different from other power sources, the potentiometer and adjustable resistance are also adjusted in the circuit.
• Wide range of voltage and frequency regulation, digital key input, independent display of three-phase voltage and line voltage
• Digital password lock, test data security and prevent important test data from being modified by misoperation

APA2000L Single phase series

Model 2000L 2001L 2002L 2003L 2005L 2010L 2015L
Output Capacity 500VA 1KVA 2KVA 3KVA 5KVA 10KVA 15KVA
Input Power 1Ø2W+G 110V/220V±10%  50/60Hz±5%
Output Frequency 50Hz/ 60Hz/ 45~500Hz
Frequency stability 0.01%
Output Voltage 0~150V/0~300V(AUTO)
Output current 4.2/2.1 8.4/4.2 16.8/8.4 25/12.5 42/21 84/42 126/63
Load Regulation ≤0.5%
Waveform Distortion ≤0.3%
Meter Display Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current
Protective Device Overload, Overcurrent, Temperature, Short Circuit, Undervoltage Protection and Alarm
Working condition ambient temperature 0~40°C   relative humidity10~90%

APA2000LS Three phase series

Model 2006LS 2010LS 2015LS 2020LS 2030LS 2045LS
Output Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 45KVA
Input Power 1Ø2W+G 220V±10% 3Ø4W+G 220V/380V±10%  50/60Hz±5%
Output Frequency 50Hz/ 60Hz/ 45~500Hz
Frequency stability 0.01%
Output Voltage 0~150V/0~300V(AUTO)
Output current 16.8/8.4 27.5/13.75 42/21 55.6/27.8 84/42 126/63
Load Regulation ≤0.5%
Waveform Distortion ≤0.3%
Meter Display Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current
Protective Device Protection and alarm of short circuit, short voltage and short phase with overload, over current and over temperatur
Working condition ambient temperature 0~40°C   relative humidity10~90%