High Performance
• Optional dual output, suitable for multi-load applications
• Quick stop output with emergency stop button
• With EF signal interlocking function
APA5000(AC)Single phase series
Model | 5000 | 5001 | 5002 | 5003 | 5005 | 5015 | 5020 | 5030 |
---|---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 15KVA | 20KVA | 30KVA |
Input Power | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz±3Hz | ||||||||
Output Frequency | Vertical/trailer type 300~ 500Hz 400Hz (Special frequencies are customized) | |||||||
Output Voltage | 115V/220V±10%(Special Voltage Accepts Customization) Resolving power 0.1V accuracy 0.5%F.S.+4counts |
|||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 126/63 | 168/84 | 250/125 |
Resolving power0.01A(500VA,1KVA) 0.1A(1KVA以上) accuracy 0.2%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | ≤1.5% (Resistive load) |
||||||
Waveform Distortion | ≤2%(Resistive load) | ≤3% (Resistive load) |
||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Input and output are equipped with no fuse switch, overload, over-current, temperature, short circuit, over-voltage/under-voltage protection and alarm | |||||||
Overload capacity | 120%(1H)150%(1M)200%(15S)Other specifications are optional (According to 25% work cycle Duty Cycle Test results) |
|||||||
Weight(kg) | 20 | 25 | 30 | 35 | 45 | 190 | 240 | 3500 |
W*H*D(mm) | 425*89*480 | 430*200*500 | 430*580*700 | 600*1260*700 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |
APA5000S(AC)Three phase series
Model | 5015S | 5020S | 5030S | 5045S | 5060S | 5075S | 5100S | 5120S |
---|---|---|---|---|---|---|---|---|
Output Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input Power | 3Ø4W+G 220V/380V±15% | |||||||
50/60Hz±3Hz | ||||||||
Output Frequency | 400Hz(Trailer type)/300~ 500Hz (Vertical type)Resolving power 0.01Hz accuracy±0.02%F.S. | |||||||
Output Voltage | 115/200V±15V Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Resolving power 0.1A accuracy 0.5%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | |||||||
Waveform Distortion | ≤2% (Resistive load) | |||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Over-voltage/under-voltage phase-gap protection and alarm with overload, over-current and over-temperature short circuit |
|||||||
Overload capacity | 125%(600S)150%(30S)200%(10S)Other specifications are optional | |||||||
(kg)Weight | 210 | 230 | 270 | 360 | 450 | 540 | 600 | 800 |
(mm)W*H*D | 510*780*710 | 600*1260*700 | 750*1500*850 | 900*1780*950 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |