AC source power & DC source power manufacturing factory
Aviation Power APA5000 Series(AC)

Aviation Power APA5000 Series(AC)

Product parameter
• LED / LCD display, clear and intuitive
• Higher power density, smaller size, lighter weight, space saving and easy to move
• The protection level is as high as IP54, and the whole machine parts are treated with three preventive measures. working temperature-40℃~50℃
• There are two types of aircraft, vertical type and Trailer type, which are convenient for airport/hangar moving or fixed-point use.
• Excellent overload capability and optional extended overload function
• More detailed protection function, can detect under-voltage/over-voltage, over-current, over-load, over-temperature, short circuit and other fault states.
• Inspection of temperature and humidity in the machine to ensure the normal use of power supply
• Three-phase power supply can withstand three-phase unbalanced load: 120° +1°; 30% unbalanced load 120° +1.5°; 100% unbalanced load 120° +2°.

Online quote

Product details

High Performance
• Optional dual output, suitable for multi-load applications
• Quick stop output with emergency stop button
• With EF signal interlocking function

APA5000(AC)Single phase series

Model 5000 5001 5002 5003 5005 5015 5020 5030
Output Capacity 500VA 1KVA 2KVA 3KVA 5KVA 15KVA 20KVA 30KVA
Input Power 1Ø2W+G 110V/220V±10% 3Ø4W+G 220V/380V±10%
50/60Hz±3Hz
Output Frequency Vertical/trailer type 300~ 500Hz 400Hz  (Special frequencies are customized)
Output Voltage 115V/220V±10%(Special Voltage Accepts Customization)
Resolving power 0.1V accuracy 0.5%F.S.+4counts
Output current 4.2/2.1 8.4/4.2 16.8/8.4 25/12.5 42/21 126/63 168/84 250/125
Resolving power0.01A(500VA,1KVA) 0.1A(1KVA以上)  accuracy 0.2%F.S.+4counts
Load Regulation ≤1%(Resistive load) ≤1.5%
(Resistive load)
Waveform Distortion ≤2%(Resistive load) ≤3%
(Resistive load)
Meter Display LED/LCD Display
Protective Device Input and output are equipped with no fuse switch, overload, over-current, temperature, short circuit, over-voltage/under-voltage protection and alarm
Overload capacity 120%(1H)150%(1M)200%(15S)Other specifications are optional
(According to 25% work cycle Duty Cycle Test results)
Weight(kg) 20 25 30 35 45 190 240 3500
W*H*D(mm) 425*89*480 430*200*500 430*580*700 600*1260*700
Working condition ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable)

APA5000S(AC)Three phase series

Model 5015S 5020S 5030S 5045S 5060S 5075S 5100S 5120S
Output Capacity 15KVA 20KVA 30KVA 45KVA 60KVA 75KVA 100KVA 120KVA
Input Power 3Ø4W+G 220V/380V±15%
50/60Hz±3Hz
Output Frequency 400Hz(Trailer type)/300~ 500Hz (Vertical type)Resolving power 0.01Hz accuracy±0.02%F.S.
Output Voltage 115/200V±15V Resolving power 0.1V accuracy 0.5%F.S.+4counts
Output current 42/21 54/27 84/42 126/63 168/84 210/105 278/139 333/166
Resolving power 0.1A  accuracy 0.5%F.S.+4counts
Load Regulation ≤1%(Resistive load)
Waveform Distortion ≤2% (Resistive load)
Meter Display LED/LCD Display
Protective Device Over-voltage/under-voltage phase-gap protection and alarm with overload,
over-current and over-temperature short circuit
Overload capacity 125%(600S)150%(30S)200%(10S)Other specifications are optional
(kg)Weight 210 230 270 360 450 540 600 800
(mm)W*H*D 510*780*710 600*1260*700 750*1500*850 900*1780*950
Working condition ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable)
Online service
Service Hotline
86-769-89616802
86-13602353727